实用器官移植电子杂志 ›› 2021, Vol. 9 ›› Issue (4): 318-321.DOI: 10.3969/j.issn.2095-5332.2021.04.013

• 论著 • 上一篇    下一篇

多普勒超声下儿童移植肾动脉血流增快35 例分析 

付嘉钊 1 ,张娟 2 ,李烟花 1 ,廖甜 3 ,熊胜 3 ,陆瀚澜 1 ,赵闻雨 1 ,曾力 1   

  1. 1. 海军军医大学第一附属医院器官移植科,上海 200433 ;

    2. 海军军医大学第三附属医院放射科,上海 200438 ;

    3. 湖南省长沙市第八医院(长沙市中医院)超声科,湖南 长沙 410100

  • 出版日期:2021-07-20 发布日期:2023-04-12
  • 基金资助:

    国家自然科学基金(81470979)


Analysis of 35 cases of accelerated renal artery flow rate in pediatric kidney transplantation under Dopplerultrasound

Fu Jiazhao 1 ,Zhang Juan 2 ,Li Yanhua 1 ,Liao Tian 3 ,Xiong Sheng 3 ,Lu Hanlan 1 ,Zhao Wenyu 1 ,Zeng Li 1 .
  

  1. 1.Department of OrganTransplantation,Changhai Hospital,Second Military Medical University,Shanghai 200433,China;
    2.Department of Radiology,Shanghai Eastern Hepatobiliary Surgery Hospital,Second Military Medical University,Shanghai 200438,China;
    3.Department ofUltrasound,Traditional Chinese Medicine Hospital of Changsha(the Eighth Hospital of Changsha),Changsha 410100,Hunan,China.
  • Online:2021-07-20 Published:2023-04-12
  • Supported by:

    Objective Stenosis of the graft arteries may lead to serious complications such as high blood pressure and even loss of the graft. Doppler ultrasonography is a simple and effective method for screening renal artery stenosis. In pediatric renal transplantation,the rate of increased flow velocity of transplanted renal artery was significantly higher than that of adult under Doppler ultrasound. Methods In this paper,we summarized 64 cases of pediatric renal transplantation in our hospital,who showed the increased flow rate of renal artery and were diagnosed of arterial stenosis. We analyzed the relationship between the detection time of the increased flow rate,the maximum flow rate,the increase of blood pressure and creatinine. Results Thirty-five of the 64 pediatric renal grafts had increased arterial flow rate. There were 16 cases with no obvious velocity increase and 19 cases withobvious velocity increase,respectively. There were 12 cases with elevated blood pressure,serum creatinine and other clinical manifestations,while 23 cases had no related clinical manifestations. Balloon dilation was effective in cases of arterial stenosis with clear imaging evidence. Conclusion Increased arterial velocity in renal graft is a common phenomenon in pediatric kidney transplantation. Most of the clinical manifestations,such as hypertension and serum creatinine increase,are only transient,and only a few of them develop artery stenosis.

摘要:

目的 移植肾动脉狭窄可能导致高血压等严重并发症,甚至移植肾丢失。多普勒超声是筛查移植肾动脉狭窄的常用手段。儿童肾移植中,在多普勒超声下检出移植肾动脉收缩期峰值流速(以下简称“动脉流速”)增快比例明显高于成人。方法 我们总结分析了本院近年来 64 例儿童肾移植中出现动脉流速增快以及确诊动脉狭窄的情况,总结分析了动脉流速增快发现时间、最快流速与血压升高、肌酐升高之间的关系。结果 64 例儿童肾移植中曾经出现过动脉流速增快的共 35 例。其中不明显增快的和明显增快的各有16 例和 19 例 ;有血压升高、血肌酐升高等临床表现的共 12 例,无相关临床表现的为 23 例。有明确影像学证据的动脉狭窄 5 例,球囊扩张术治疗可取得良好效果。结论 动脉流速增快是儿童肾移植常见现象,大多数与之相关的高血压、血肌酐升高等临床表现仅一过性出现,极少数发展为动脉狭窄。多数动脉流速增快,可暂不积极处理并予密切监测。保守治疗无效时,再考虑血管造影下球囊扩张等积极治疗方法,可取得较好疗效。

关键词: 儿童肾移植 , ,  , 动脉狭窄 , ,  , 超声诊

Key words: